Our certified firestop inspection service assesses all penetration seals at cable trays, pipe runs, and wall openings to verify they will contain fire and smoke. We follow NFPA 101, UL listing requirements, and Saudi Civil Defense standards, issuing detailed inspection reports accepted by local authorities.
We verify that fireproofing materials — including intumescent coatings and sprayed mineral fiber — are correctly applied to structural steel, beams, and columns. Our inspection confirms adequate thickness, adhesion, and condition to guarantee structural integrity during fire exposure, meeting SASO and ASTM E119 standards.
Coating failures cause billions in annual corrosion damage across the Gulf region. Our paint thickness inspection service uses calibrated, NACE-certified dry film thickness gauges to verify that protective coatings meet project specifications — safeguarding pipelines, tanks, and structures against the harsh Saudi climate.
Hidden water leaks cause structural damage, mold growth, and costly emergency repairs. Our advanced water leakage inspection uses acoustic detection, thermal imaging, and tracer dye techniques to pinpoint leaks in buildings, underground pipelines, and infrastructure without destructive opening of walls or floors.
FM200 (HFC-227ea) suppression systems depend on the protected enclosure retaining enough gas concentration to extinguish fire. Our door fan test — conducted per NFPA 2001 and ISO 14520 — measures air leakage and calculates the predicted hold time, confirming the room will maintain design concentration throughout the fire event.
Evaluate building enclosure tightness to identify air leakage points. Our testing improves energy efficiency, safety, and environmental control within facilities.
Uncontrolled air leakage within a building structure — through partitions, ceiling voids, and mechanical shafts — undermines HVAC performance and indoor air quality. Our component-level air leakage testing isolates problem areas and provides actionable data to restore system balance and occupant comfort.
Leaky ductwork wastes 20–30% of conditioned air before it reaches occupied spaces — a critical loss in Saudi Arabia’s climate. Our duct leakage testing measures total and component leakage using pressurization equipment, diagnoses problem sections, and produces reports required for commissioning and ASHRAE 90.1 compliance.
Smoke testing is a rapid, visual method for confirming the integrity of air distribution systems, identifying containment breaches, and verifying that pressurized smoke-control systems will perform as designed. We use non-toxic, UL-listed smoke cartridges and professional injection equipment for precise, safe results.
Our Level II certified thermographers use professional-grade FLIR infrared cameras to detect overheating electrical connections, insulation voids, moisture infiltration, and HVAC inefficiencies that are invisible to the naked eye. Thermography is the most cost-effective predictive maintenance tool available for Saudi Arabian facilities.